1.
Verify that the LEDs on the switch indicate that all components are healthy. (LED patterns are
described in
a.
Verify that the LEDs are not set to "beacon" (this can be determined through the switchShow
command or Web Tools). For information about how to turn beaconing on and off, see the
HP StorageWorks Fabric OS administrator guide or the Web Tools administrator's guide.
b.
Follow the recommended action for the observed LED behavior, as listed in
Table
2.
Verify that the switch prompt displays on the terminal of a computer workstation that is connected
to the switch.
If the prompt does not display when POST completes, press Enter. If the prompt still does not
display, open another Telnet session or access the switch through another management tool. If
this is not successful, the switch did not successfully complete POST. Contact the switch supplier.
3.
Using either Web Tools or the CLI, verify that the diagnostic status for all ports in the switch is
OK.
• If you are using Web Tools, select Port Admin or Status to display information about the ports.
• If you are using the CLI, use the diagShow command.
4.
Review the system log for errors.
• If you are using Web Tools, errors are listed under Switch Events.
• If you are using the CLI, errors detected during POST are written to the system log, which is
viewed using the errShow command. For more information about this command, see the
Fabric OS Message Reference.

Maintaining the 8-Gb SAN Switches

The 8-Gb SAN Switches are designed for high availability and low failure; they do not require any
regular physical maintenance. They include diagnostic tests and field-replaceable units (FRUs) for the
8/40, 8/80, Encryption SAN Switch, and FCoE Converged Network Switch, as described in the
following sections.

Installing an SFP

The 8-Gb SAN Switches support only HP-branded SFPs.
nl
See
"Supported SFP transceiver
If you use an unqualified SFP, the switchShow command output will show the port in an Mod_Inv
state. Additionally, the firmware will also log the issue in the system error log.
To install an SFP:
1.
Verify that the bail (wire handle) is in the unlocked position (see
2.
Place the SFP in the correctly oriented position on the port.
NOTE:
Each SFP has a gold-plated PCB-edge connector on the bottom. The correct position to insert
an SFP into the upper row of ports is with the gold edge down. The correct position to insert
an SFP into the lower row of ports is with the gold edge up.
3.
Slide the SFP into the port until you feel it click into place; then close the bail.