Fcoe Converged Network Switch Port Side Led Patterns - HP StorageWorks 8/40 - SAN Switch Hardware Reference Manual

Storageworks 8-gb san switch series
Hide thumbs Also See for StorageWorks 8/40 - SAN Switch:
Table of Contents

Advertisement

Table 14 FCoE Converged Network Switch port side LED patterns
LED name
LED color
No light
Power status
Steady green
System status
No light
Steady green
Steady amber (for
more than five
seconds)
Flashing amber
Ethernet speed
(Management
No light
port)
Steady green
Ethernet activ-
No light
ity/Link (Man-
agement port)
Steady green
Blinking green
Optical media
Off
port status (two-
color LED for
each FC and
Steady amber
CEE port)
66
Managing the 8-Gb SAN Switches
Status of hardware
System is off or there is an intern-
al power supply failure.
System is on and power supplies
are functioning properly.
System is off or there is no
power.
System is on and functioning
properly.
Unknown state, boot failed, or
the system is faulty. This LED
displays steady amber during
POST. This is normal and does
not indicate a fault.
Attention is required. Several
variables can cause this status,
including a power supply fail-
ure, fan failure, or if one or
more environmental ranges have
been exceeded.
Port speed is 10 Mb/s.
Port speed is 100/1000 Mb/s.
There is no link.
There is a link.
There is link activity (traffic).
No light or signal carrier on
media interface
Receiving light or carrier, but
not online
Recommended action
Verify the following:
System is powered on (power
supply switches to 1)
The power cables are attached.
The power source is live.
If the system power LED is not
green, the unit may be faulty.
Contact your switch service pro-
vider.
No action required.
Verify that the system is on and has
completed booting.
No action required.
Perform the following steps:
1.
Connect a serial cable to the
system.
2.
Reboot the system.
3.
Check the failure indicated on
the system console.
4.
Contact your switch service
provider.
Check the management interface
and the error log for details on the
cause of the status. Contact your
switch service provider.
No action required.
No action required.
Verify that the Ethernet cable is
connected properly.
No action required.
No action required.
Verify that the transceiver is in-
stalled correctly and the cable is
connected correctly.
No action required.