Table 4-12: Mir Ranges And Defaults - Alvarion BreezeACCESS VL System Manual

Hide thumbs Also See for BreezeACCESS VL:
Table of Contents

Advertisement

The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
4.2.6.6.2.2 MIR: Uplink (SU only)
Sets the Maximum Information Rate of the up-link from the SU to the AU. The
MIR value cannot be lower than the corresponding CIR value.
Available values range and default value are shown in Table 4-14.
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
4.2.6.6.2.3 CIR: Downlink (SU only)
Sets the Committed Information Rate of the downlink from the AU to the SU. The
CIR value cannot be higher than the corresponding MIR value.
Available values range and default value are shown in Table 4-15.
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
4.2.6.6.2.4 CIR: Uplink (SU only)
Sets the Committed Information Rate of the uplink from the SU to the AU. The
CIR value cannot be higher than the corresponding MIR value.
Available values range and default value are shown in Table 4-15.
The actual value will be the entered value rounded to the nearest multiple of 128
(N*128).
Unit
Range (Kbps)
Type
SU-3
128-2,048
SU-6
128-4,096
SU-8
128-13,440
SU-54
128-53,888
SU-I
128-4,096
Operation and Administration
Table 4-14: MIR Ranges and Defaults
MIR Uplink
Default (Kbps)
2,048
4,096
13,440
53,888
4,096
MIR Downlink
Range (Kbps)
128-3,072
3,072
128-6,016
6,016
128-13,440
13,440
128-53,888
53,888
128-6,016
6,016
Menus and Parameters
Default (Kbps)
195