Chapter 4 - Operation and Administration
The default is 8.
4.2.6.2.19.2.4
KeepLink (AU only)
Activates or deactivates the KeepLink feature:
0 – Disable KeepLink
1 – Enable KeepLink
The default is 1 (Enabled).
4.2.6.2.19.2.5
Channel Scan Period
The period of time, in seconds, the unit will stay on each channel to gather
information. The unit may stop recording prematurely if a 100 000 events limit is
reached.
The available range is from 2 to 30 minutes.
The default is 5 minutes.
4.2.6.2.19.2.6
Automatic Scan Period
The period of time, in minutes, after which the unit will rerun the Interference
Mitigation channel scan. Setting this value to 0 will disable periodicity, allowing
only one-time manually triggered Interference Mitigation scans.
The available range is 0 (disabled) or 10 - 10080 (minutes)
Default value is 0 (disabled).
4.2.6.2.19.2.7
Frequency Subset (AU only)
This setting allows you to select the channels that will be scanned during the
Interference Mitigation process. All the defined frequencies and their indexes will
be displayed. Frequencies are indexed with consecutive numbers starting from 1.
Enter the desired channels' corresponding indexes separated by commas (for
example: 1, 4, 5, 6, 14, 18, 19) or enter A to select all defined frequencies.
4.2.6.2.19.3 Activation
Starts the Interference Mitigation process. Keep in mind that during the scan, the
AU will lose connectivity to the associated SUs. A final validation is required prior
to the scan:
0 – Cancel Operation
1 – Activate Interference Mitigation (Causes Automatic Reset)
160
BreezeACCESS VL System Manual