Appendix F - Troubleshooting
F.1

Ethernet Port Connection Problems

Problem and Indication
The Ethernet Integrity Indicator (the yellow
LED embedded in the Ethernet connector)
is off, and/or the Ethernet Activity Indicator
(the green embedded LED) does not blink
when there should be traffic on the Ethernet
port.
The unit does not respond to ping.
* If the IP parameters of the unit are unknown, use the Set Factory Defaults utility to restore
the default factory configuration of all parameters (except to Passwords, general FTP
parameters and AU's Frequency). The IP address of the unit after setting to factory defaults is
10.0.0.1.
238
Possible Cause
Wrong type of Ethernet
If connected directly to PC-use a
cable
crossed cable. Otherwise-use a
straight cable
Faulty Ethernet cable
Replace cable
Wrong IP configuration
Make sure that the PC is on the same
subnet as the unit*.
Wrong Ethernet port
Make sure that the speed and duplex
operation mode
settings in the PC match the
configuration in the unit (the default is
Auto Negotiation)
Wrong Management
Make sure all relevant parameters are
VLAN, User Filtering,
configured properly
Access to
Management..
Corrective Action