Change Password - Alvarion BreezeACCESS VL System Manual

Hide thumbs Also See for BreezeACCESS VL:
Table of Contents

Advertisement

4.2.3.2.1.4 Set Partial Operator Defaults
Select this option to reset the unit to the Operator Defaults configuration,
excluding the parameters that are required to maintain connectivity and
management access. The parameters that do not change after Set Partial
Operator Defaults are listed in Table 4-3.
4.2.3.2.1.5 Cancel Current Pending Request
After selecting one of the Set defaults options, it will be executed after the next
reset. This option enables to cancel the pending request before execution
(provided the unit has not been reset yet).
4.2.3.2.2 Save Current Configuration As Operator Defaults
The Save Current Configuration As Operator Defaults enables defining the
current configuration of the unit as the Operator Defaults configuration.
4.2.3.3
Change Unit Name
The Change Unit Name option enables changing the name of the unit, which is
also the system's name in the MIB2. The name of the unit is also used as the
prompt at the bottom of each Monitor window.
Valid values: A string of up to 32 printable ASCII characters.
The default unit name is an empty string.
4.2.3.4

Change Password

The Change Password submenu enables changing the access password(s). The
Change Password submenu is available only to users with Administrator access
rights.
Valid values: A string of up to 8 printable ASCII characters.
Refer to section
levels.
4.2.3.5
Flash Memory Control
The Flash Memory Control submenu enables selecting the active software version
for the unit.
The flash memory can store two software versions. One version is called Main and
the other is called Shadow. New software versions are loaded as the shadow
version. You can select the shadow version as the new active version by selecting
Reset and Boot from Shadow Version. However, after the next reset, the main
version is re-activated. To continue using the currently active version after the
next reset, select Use Running Version After Reset: The previous shadow
version will be the new main version, and vice versa.
Operation and Administration
4.1
for a list of the default passwords for each of the access
Menus and Parameters
103

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents