D-Link DES-3010FA/GA CLI Reference Guide
Example
The following example configures the following alarm conditions:
•
Alarm index — 1000
•
Sample interval — 360000 seconds
•
Rising threshold — 1000000
•
Falling threshold — 1000000
•
Rising threshold event index — 10
•
Falling threshold event index — 20 show rmon alarm-table
The show rmon alarm-table User EXEC mode command displays the alarms table.
Syntax
show rmon alarm-table
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the alarms table.
Console> show rmon alarm-table
Index
OID
-----
----------------------
1
1.3.6.1.2.1.2.2.1.10.1
2
1.3.6.1.2.1.2.2.1.10.1
3
1.3.6.1.2.1.2.2.1.10.9
The following table describes significant fields shown above:
Field
Desc ription
Index
An index that uniquely identifies the entry.
OID
Monitored variable OID.
Owner
The entity that configured this entry.
Owner
-------
CLI
Manager
CLI
Page 189