Biamp System Parameters - Tannoy V300 User Manual

Hide thumbs Also See for V300:
Table of Contents

Advertisement

13.3 Biamp System Parameters

Parameter
Gain
Delay
Polarity
HPF â
LPF
PEQ 1 â â
PEQ 2
PEQ 3
PEQ 4
PEQ 5
â â
Note : When using the V300 with subs, set HPF on LF section @ 80 – 100Hz
(24dB/oct LR) and omit PEQ1 (on LF only)
PEQ 1 (on LF only) may also be omitted when using the V300 as a floor monitor.
Unit/Name
Low Section
(dB)
0
(ms)
0
Positive
Freq (Hz)
45.1
Slope (dB/oct)
24
Filter Shape
Butterworth
Freq (Hz)
1820
Slope (dB/oct)
24
Filter Shape
Linkwitz Riley
Freq (Hz)
60.1
Level (dB)
+7
Type
Parametric
Q / Bandwidth
2.8 / 0.3536
Freq (Hz)
281
Level (dB)
-2.5
Type
Parametric
Q / Bandwidth
2 / 0.500
Freq (Hz)
749
Level (dB)
-2
Type
Parametric
Q / Bandwidth
2 / 0.500
Freq (Hz)
606
Level (dB)
-2
Type
Parametric
Q / Bandwidth
6 / 1.669
Freq (Hz)
1650
Level (dB)
-2
Type
Parametric
Q / Bandwidth
7.1 / 0.1403
High Section
-6
0
Positive
1920
24
Linkwitz Riley
Thru
NA
NA
6100
+3.5
Hi - Shelf
NA
10500
+4
Parametric
9.5 / 0.1051
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents