Hot Swap Subsystem SCSI Address Settings

Switches 3, 4, and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The
following table describes the settings and the resulting shelf SCSI address.
NOTE
Switch
Settings
3 - Off
4 - Off
6 - Off
3 - Off
4 - On
6 - Off
3 - On
4 - Off
6 - Off
3 - On
4 - On
6 - Off

Specifications

Power Supply
Power Availability
Power Consumption
System Dimensions
System Weight
Operating Temperature
Operating Humidity
For information on changing the SCSI address setting on the CD-ROM drive, see the
Technical Information Label on the CD-ROM drive.
Upper Cage
SCSI Address
Shelf 1 = ID 1
Shelf 2 = ID 2
Shelf 3 = ID 3
Shelf 1 = ID 1
Shelf 2 = ID 0
Shelf 3 = ID 3
Shelf 1 = ID 9
Shelf 2 = ID 10
Shelf 3 = ID 11
Shelf 1 = ID 9
Shelf 2 = ID 8
Shelf 3 = ID 11
Auto-ranging 90 to 135 VAC, or 180 to 265 VAC at 50-60Hz
470W continuous, 530W peak
723W maximum with 110/220V supply
815W peak with 110/220V supply
19.3 in. high x 13.7 in wide x 18.1 in deep
(49 cm high x 34.8 cm wide x 46 cm deep)
50-70 lbs (22.7-31.8 kg), depending on configuration
41 to 95 degrees F (5 to 35 degrees C)
20% to 80% non-condensing
Lower Cage
Switch
SCSI Address
Settings
3 - Off
Shelf 4 = ID 4
4 - Off
Shelf 5 = ID 5
6 - On
Shelf 6 = ID 6
3 - Off
Shelf 4 = ID 4
4 - On
Shelf 5 = ID 0
6 - On
Shelf 6 = ID 6
3 - On
Shelf 4 = ID 12
4 - Off
Shelf 5 = ID 13
6 - On
Shelf 6 = ID 14
3 - On
Shelf 4 = ID 12
4 - On
Shelf 5 = ID 8
6 - On
Shelf 6 = ID 14