Specifications - HP LC2000r - NetServer - 128 MB RAM Handbook

Hp netserver service handbook, volume 2 - mid
Hide thumbs Also See for LC2000r - NetServer - 128 MB RAM:
Table of Contents

Advertisement

Hot Swap Subsystem SCSI Address Settings
Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap subsystem. The
following table describes the settings and the resulting shelf SCSI address.
NOTE
Upper Cage
Switch
SCSI Address
Settings
3 - Off
Shelf 1 = ID 1
4 - Off
Shelf 2 = ID 2
6 - Off
Shelf 3 = ID 3
3 - Off
Shelf 1 = ID 1
4 - On
Shelf 2 = ID 0
6 - Off
Shelf 3 = ID 3

Specifications

Power Supply
Power Availability
Power Consumption
System Dimensions
System Weight
Operating Temperature
Operating Humidity
BTUs
90
For information on changing the SCSI address setting on the CD-ROM drive, see the
Technical Information Label on the CD-ROM drive.
Switch
Settings
3 - Off
4 - Off
6 - On
3 - Off
4 - On
6 - On
Auto-ranging 90 to 132 VAC, or 180 to 264 VAC at 47-63Hz
LH/LH Plus 350W continuous, 386W peak
LH Pro 450W continuous
LH/LH Plus: 499/479W maximum with 110/220V supply
551/528W peak with 110/220V supply
LH Pro: 650/600 maximum with 110/220V
19.3 in. high x 13.7 in wide x 18.1 in deep
(49 cm high x 34.8 cm wide x 46 cm deep)
50-70 lbs (22.7-31.8 kg), depending on configuration
41 to 95 degrees F (5 to 35 degrees C)
20% to 80% non-condensing
LH/LH Plus: less than 1700 BTUs (430 Kcal)
LH Pro: less than 2200 BTUs (560 KCal)
Lower Cage
SCSI Address
Shelf 4 = ID 4
Shelf 5 = ID 5
Shelf 6 = ID 6
Shelf 4 = ID 4
Shelf 5 = ID 0
Shelf 6 = ID 6

Hide quick links:

Advertisement

Table of Contents
loading