Hot Swap Subsystem Scsi Address Settings - HP D5970A - NetServer - LCII User Manual

Hp netserver lh pro user guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 3

Hot Swap Subsystem SCSI Address Settings

Switches 4 and 6 determine the SCSI address setting for each shelf in the hot swap
subsystem. Table 3-2 lists the shelf SCSI address for each switch setting.
NOTE
For information on changing the SCSI address setting on the
CD-ROM drive, see the Technical Information Label on the
CD-ROM drive.
Upper Cage
Switch Settings
3 - Off
4 - Off
6 - Off
3 - Off
4 - On
6 - Off
3 - On
4 - Off
6 - Off
3 - On
4 - On
6 - Off
Table 3-2. SCSI Address Settings
SCSI Address
Switch Settings
3 - Off
Shelf 1 = ID 1
Shelf 2 = ID 2
4 - Off
Shelf 3 = ID 3
6 - On
Shelf 1 = ID 1
3 - Off
Shelf 2 = ID 0
4 - On
Shelf 3 = ID 3
6 - On
Shelf 1 = ID 9
3 - On
Shelf 2 = ID 10
4 - Off
Shelf 3 = ID 11
6 - On
Shelf 1 = ID 9
3 - On
Shelf 2 = ID 8
4 - On
Shelf 3 = ID 11
6 - On
Configuring Mass Storage
Lower Cage
SCSI Address
Shelf 4 = ID 4
Shelf 5 = ID 5
Shelf 6 = ID 6
Shelf 4 = ID 4
Shelf 5 = ID 0
Shelf 6 = ID 6
Shelf 4 = ID 12
Shelf 5 = ID 13
Shelf 6 = ID 14
Shelf 4 = ID 12
Shelf 5 = ID 8
Shelf 6 = ID 14
17

Advertisement

Table of Contents
loading

Table of Contents