Configuring the Server

Configuring the Drive Array Controller

If you are using a simple SCSI controller to boot from the internal drives, disregard
this section and proceed to the "Installing the Operating System" section later in this
chapter. If you are using a Smart Array 5i Controller or an array controller installed
in a PCI/PCI-X slot to boot from the internal drives the first time the system is
powered up, you must create the logical drive (or drives) in the RAID array.
The Smart Array 5i Controller built into the ProLiant DL740 server can use any of
the following utilities to create logical drives based on the RAID configuration that
you specify:
Option ROM Configuration for Arrays (ORCA)
Array Configuration Utility (ACU)
Array Configuration Replicator Utility (ACR)
The Smart Array 5i Controller is a dual-channel Ultra3 SCSI array controller
embedded on the I/O board. Both channels support Low Voltage Differential (LVD)
SCSI devices. The controller provides the following features:
32 MB of total memory with 12 MB of read-ahead cache
Support for up to four internal Ultra3 SCSI hot-plug drives in RAID 0, 1, 1+0,
and 5 configurations
External connector support for external tape drives to back up the internal drives
Migration between RAID levels
Migration between stripe sizes
Prefailure notification and Pre-Failure Warranty (through Insight Manager 7)
Online spares
Port 2 is dedicated to controlling the SCSI drives in the internal drive bay.