Server Specifications
Table F-1: ProLiant DL740 Server Specifications
Dimensions
Height
Depth
Width
Weight (no drives and two power supplies)
Input requirements (per power supply)
Rated input voltage
Rated input frequency
Rated input current
Power supply output power (per power
supply)
Rated Steady-State Power
Temperature range
Operating
Shipping
Relative humidity (noncondensing)
Operating
Nonoperating
Maximum wet bulb temperature
* Altitude derating: 1
HP ProLiant DL740 Server User Guide
o
C/1000 ft to 10,000 feet
Server Specifications
7.0 in
28.5 in
17.5 in
125 lb
Low range
100 to 120 V
50 to 60 Hz
8 A
Low range
800 W
°
°
50
to 95
F
°
°
-22
to 122
F
10% to 90%
5% to 90%
°
101.7
F
F
17.8 cm
72.4 cm
44.5 cm
56.7 kg
High range
200 to 240 V
50 to 60 Hz
10 A
High range
1100 W
°
°
10
to 35
C*
°
°
-30
to 60
C
10% to 90%
5% to 90%
°
38.7
C
F-1