4. Select the Array Configuration Utility program.
When you start the ACU, the software checks the configuration of each controller
and its drive arrays. The ACU defaults to the standard configuration path. If you
would like to run the configuration wizards, select them from the right-hand side of
the screen.
Online Help
The configuration wizards contain context-sensitive help on the right hand side of
the screen. To access more detailed help, or for help on the standard configuration
screens, click help on the top right of the screen.
Running ACU from the Operating System
If the server that you are configuring is running in Windows 2000, Windows Server
2003, or Linux, you can install and run the configuration utility online:
Windows 2000 and Windows Server 2003—When you install the ProLiant
Support Pack for Windows 2000 and the ProLiant Support Pack for
Windows Server 2003, the ACU is automatically installed on the server.
Linux—The Array Configuration Utility is available for download from the HP
website:
h18000.www1.hp.com/products/servers/linux/softwaredrivers.html
Refer to the README.TXT file included with the utility for version support
information and instructions about loading the utility.
Capacity Expansion
Capacity expansion involves adding storage capacity to an array that has already
been configured. If an existing array is nearly full of data, you can expand the
capacity without disturbing the existing data. The Smart Array 5i capacity expansion
feature allows new physical drives to be added to the array.