Install Chassis Retention Bracket When Shipping An Hp Rack - HP D7171A - NetServer - LPr Manual

Pedestal-to-rack conversion guide
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

Chapter 3
Install Chassis Retention Bracket when Shipping
an HP Rack
For the HP rack, the rack nuts for the chassis retention bracket were installed on
the right rear rack column.
For the HP rack, install the chassis retention bracket and secure the NetServer to
it, as follows:
1. Position the bracket as shown in Figure 3-9.
Figure 3-9. Screw Bracket to Rack and NetServer (Shown for HP NetServer
LH 3r; Number of Power Supply Modules May Vary)
NOTE
The Chassis Retention Bracket is only required for shipping the
system in an HP rack.
2. Fasten the bracket to the rack with the two 10x32 screws.
3. Fasten the bracket to the NetServer with the two 6x32 screws.
For the HP rack with an anti-tip foot, retract the anti-tip foot if other components
will not be extended from the front of the rack.
32
Conversion: Install Components, Cover, and Front Bezel
Right Rear Column
of HP Rack
Hole 13 above Base Line
Rack Nuts
Hole 9 above Base Line
Chassis Retention
Bracket