Pedestal-to-rack conversion guide
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

Chapter 3
3. Mark locations on the rack columns for all bar nuts and rack nuts to hold
the rack slides and bezel mounting hardware.
For HP racks, use the appropriate rack installation template for your
rack:
For HP Systems racks, use the installation template labeled LH 3r
(HP Systems), the installation template labeled LH 4r (HP Systems),
or the installation template labeled LH 3000r and LH 6000r (HP
Systems).
For HP Rack System/E racks and HP Rack System/U racks, use
the installation template labeled LH 3r (HP Rack System/E), the
installation template labeled LH 4r (HP Rack System/E), or the
installation template labeled LH 3000r and LH 6000r (HP Rack
System/E).
Be sure to mark holes 9 and 13 above the base line for the rack nuts that
will hold the chassis retention bracket.
For Compaq racks, count up from the top of the unit below, marking
the 20th and 22nd holes on all four columns, as described in the HP
NetServer LH 3r, LH 4r, LH 3000r, and LH 6000r Installation Guide
®
for Compaq
4. Install all bar nuts and rack nuts to hold the rack slides and bezel mounting
hardware.
For HP racks, be sure to install the rack nuts for the chassis retention
bracket, as shown in Figure 3-5.
Conversion: Install Components, Cover, and Front Bezel
4000/7000 Racks.
25