Replication Manager can use the disk configuration definition file and the copy
group definition file with the prefix specified here.
local-site's-DAD-ID ~ <DAD string consisting of 1 to 28 characters>
Specifies the device address domain ID of the local site on which the Business
Continuity Manager agent is operating. This is the value specified in Local Device
Address Domain ID in Business Continuity Manager's Set Defaults panel. When
monitoring PPRC copy pairs, specify the value specified in Device Address Domain,
Primary or Device Address Domain, Secondary in the Scan Copy Pair Inside Storage
System panel of Business Continuity Manager.
If you specify multiple PREFIX parameters, HP recommends that you use the same
device address domain ID for all of the device address domain IDs on the local
site.
NOTE:
Do not specify the local site's Non Gen'ed device address domain ID or
the remote site's device address domain ID.
route-list-ID ~ <ROUTE string consisting of 1 to 8 characters>
Specifies the route list ID that is used by the Business Continuity Manager agent
when the Remote DKC Control Function is used. This is the value specified in Preset
RouteListID in Business Continuity Manager's Set Defaults panel.
You must specify the route list ID in order to use the Remote DKC Control Function.
local-site's-Non-Gen'ed-DAD-ID ~ <DAD string consisting of from 1 to 28 characters>
Specifies the Non Gen'ed device address domain ID used by the local site on which
the Business Continuity Manager is operating.
Specify an asterisk (*) in place of the local site's Non Gen'ed device address
domain ID to omit it while specifying the following value (remote site's device
address domain ID).
Note also that to acquire information about Non Gen'ed volumes, you must specify
the local site's Non Gen'ed device address domain ID.
NOTE:
Do not specify the local site's device address domain ID or the remote site's
device address domain ID.
If you specify multiple PREFIX parameters, specify the same device address
domain ID for all of the local site's Non Gen'ed device address domain IDs.
remote-site's-DAD-ID ~ <DAD string consisting of from 1 to 28 characters...>
Specifies the device address domain ID of the remote site on which the Business
Continuity Manager agent performs remote scans.
To specify multiple device address domain IDs, separate consecutive device address
domain IDs with a colon (:), as shown in the following example:
Example: DAD1:DAD2:...