[Install] Volume To Space; Maintenance Descriptions; [Maintenance] Blockade - HP StorageWorks P9000 Reference Manual

Audit log user and reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

[Install] Volume to Space

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Volume to Space,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{PG,LDKC:CU:LDEV}=[{1-1,0x00:0x00:0x01},{1-1-(1),
0x00:0x00:0x02}],Num. of LDEVs=2
Detailed information
Item
PG
LDKC:CU:LDEV
Num. of LDEVs

Maintenance descriptions

[Maintenance] Blockade

Example 1: blocking a PCB
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Blockade,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PCB=[CHA-1EU],Num. of PCBs=1
Example 2: blocking an LDEV
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance],Blockade,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PG=[1-1],Num. of PGs=1
Detailed information
Item
PCB
Num. of PCBs
PDEV
PG
Num. of PGs
LDEV
Num. of LDEVs
94
Audit log examples
Description
The parity group number.
E1- 1 : In case of an external volume. V1- 1 : In case of a virtual volume. X1- 1 : In case of a Thin
Provisioning volume.
The LDKC number, the CU number and the LDEV number.
The number of LDEVs.
Description
The mounting location of the PCB (Channel Adapter (CHA), Disk Adapter (DKA), CM, or MPB)to
be blocked.
The number PCB to be blocked.
The mounting location of the PDEV (physical device) to be blocked.
The parity group number.
E1- 1 : In case of an external volume. V1- 1 : In case of a virtual volume. X1- 1 : In case of a Thin
Provisioning volume.
The number of parity groups.
The LDKC number, the CU number, and the LDEV number.
The number of LDEVs.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents