Cf_Source Command; Cf_Input1 Command; Cf_Input2 Command - Sanyo PLC-XU300A - 3000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU300A - 3000 Lumens:
Table of Contents

Advertisement

PLC-XU300/350 Expand Serial Command Functional Specifications
8.6.2

CF_SOURCE Command

Command
"CF_SOURCE_%1"[CR]
Input is
Computer 1
Input is
Computer 2
%1
Input is Video
Input is
S-video
Select Source of currently selected Input
When Input specified by %1 is inappropriate for selected Input, the projector
Details
returns "101" and the command is not executed.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.6.3

CF_INPUT1 Command

Command
"CF_INPUT1_%1_"[CR]
"ANALOG" ----------Select Analog RGB Input
%1
"YPBPR" ------------- Select Component
"SCART" ------------- Select SCART
Select Computer 1 input and source specified by %1 at the same time.
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.6.4

CF_INPUT2 Command

Command
"CF_INPUT2_%1_"[CR]
%1
"ANALOG" ---------- Select Analog RGB Input
Select Computer 2 input and source specified by %1 at the same time.
This command is available in normal Power ON status.
Details
Projector returns "101" by selecting Computer 2 while Monitor out is selected in
Terminal menu.
Acceptable
Response
Unacceptable
"ANALOG" --------- Select Analog Input
"YPBPR" ----------- Select Component Input
"SCART" ----------- Select Scart Input
"UP" ---------------- Switch Input as follows
Analog →YPBPR →Scart →...
"DN" ---------------- Switch Input as follows
Scart →YPBPR →Analog →...
"DIGITAL" ---------- Select DVI Input
"UP" ---------------- Switch Input as follows
DIGITAL → HDCP →ANALOG → DIGITAL ...
"DN" ---------------- Switch Input as follows
ANALOG → HDCP → DIGITAL →ANALOG → ...
Although
no
operation
parameter "UP" /"DN"
"VIDEO" ------------- Select Composite Video Input
"UP"
"DN"
Although
no
operation
parameter "UP" /"DN"
"Sÿ VIDEO" -------- Select S-Video Input
"UP"
"DN"
Although
no
operation
parameter "UP" /"DN"
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
24 / 66
is
executed,
projector
is
executed,
projector
is
executed,
projector
accepts
accepts
accepts