Lamp Command; Cf_Lampmode Command; Cf_Lamplifecontrl Command - Sanyo PLC-XU300A - 3000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU300A - 3000 Lumens:
Table of Contents

Advertisement

PLC-XU300/350 Expand Serial Command Functional Specifications

8.8 Lamp Command

8.8.1

CF_LAMPMODE Command

Command
"CF_LAMPMODE_%1"[CR]
"NORMAL" ------- Set lamp to Normal mode status
"ECO" ------------- Set lamp to 3L mode status
%1
"UP" --------------- Switch Lamp mode forward
"DN" --------------- Switch Lamp mode backward
Select Lamp Mode
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.8.2

CF_LAMPLIFECONTRL Command

Command
"CF_LAMPLIFECONTRL_%1"[CR]
"MODE1"-----Set Lamp life mode to Mode1
%1
"MODE2"-----Set Lamp life mode to Mode2
Select Lamp life mode
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
30 / 66

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xu350a - 3500Plc-xu300Plc-xu350

Table of Contents