PLC-XU300/350 Expand Serial Command Functional Specifications
9.4.4
CR_TINT Command
Command
"CR_TINT"[CR]
Details
Get Tint value of user control
Acceptable
%a
Response
Unacceptable
9.4.5
CR_SHARP Command
Command
"CR_SHARP"[CR]
Details
Get Sharpness value of user control
Acceptable
Response
%a
Unacceptable
9.4.6
CR_GAMMA Command
Command
"CR_GAMMA"[CR]
Details
Get Gamma value of user control
Acceptable
Response
%a
Unacceptable
9.4.7
CR_WBAL – R Command
Command
"CR_WBAL-R"[CR]
Details
Get White Balance Red value of user control
Acceptable
Response
%a
Unacceptable
9.4.8
CR_WBAL – G Command
Command
"CR_WBAL-G"[CR]
Details
Get White Balance Green value of user control
Acceptable
Response
%a
Unacceptable
9.4.9
CR_WBAL – B Command
Command
"CR_WBAL-B"[CR]
Details
Get White Balance Blue value of user control
Acceptable
Response
%a
Unacceptable
"000_%a"[CR]
"000"~"063"
"Error Code"[CR] ----- When the command is invalid due to
condition such as Input source
"000_%a"[CR]
"000"~"015"
"Error Code"[CR]
"000_%a"[CR]
"000"~"015"
"Error Code"[CR]
"000_%a"[CR]
"000"~"063"
"Error Code"[CR]
"000_%a"[CR]
"000"~"063"
"Error Code"[CR]
"000_%a"[CR]
"000"~"063"
"Error Code"[CR]
43 / 66