Image Command; Cf_Bright Command; Cf_Cont Command; Cf_Color Command - Sanyo PLC-XU300A - 3000 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU300A - 3000 Lumens:
Table of Contents

Advertisement

PLC-XU300/350 Expand Serial Command Functional Specifications

8.4 Image Command

8.4.1

CF_BRIGHT Command

Command
"CF_BRIGHT_%1"[CR]
"000~063" --------------- Directly select Brightness setting value
%1
"UP" ----------------------- Current Brightness setting value + 1
"DN" ----------------------- Current Brightness setting value – 1
Set Brightness value of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.2

CF_CONT Command

Command
"CF_CONT_ÿ 1"[CR]
"000~063" --------------- Directly select Contrast setting value
%1
"UP" ----------------------- Current Contrast setting value + 1
"DN" ----------------------- Current Contrast setting value – 1
Set Contrast value of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.3

CF_COLOR Command

Command
"CF_COLOR_%1"[CR]
"000~063" ---------------- Directly select Color setting value
%1
"UP" ------------------------ Current Color setting value + 1
"DN" ------------------------ Current Color setting value - 1
Set Color value of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.4

CF_TINT Command

Command
"CF_TINT_%1"[CR]
"000~063" --------------- Directly select Tint setting value
%1
"UP" ----------------------- Current Tint setting value + 1
"DN" ----------------------- Current Tint setting value – 1
Set Tint value of user control
The value set by this command will not be saved to projector. Therefore, when
Details
turning into Stanby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
16 / 66

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-xu350a - 3500Plc-xu300Plc-xu350

Table of Contents