FAIL
(Power Supply
Failure)
Communication Ports

PCI Hot Plug Slot LEDs

Slots P7 through P10 on the I/O baseboard are 64-bit PCI slots that can be individually powered down
through system software. These four PCI Hot Plug slots each have two LEDs. The LEDs are on the I/O
baseboard, but you can see them through the server's rear panel. The green LED indicates whether power to
the slot is on or off. The amber LED indicates whether the slot needs attention.
Green LED
Amber LED
On
Off
On
On
Off
On
Off
Off
34
Lights solid yellow when power supply fails. Blinks yellow when power
supply is drawing more current than it should, because of a short-circuit in
the power supply or elsewhere in the server. If the short is in the power
supply, the power supply shuts down. If the short is in the server, the
server shuts down.
Power to the slot is on, and the slot is operating normally. Do not
remove the board from the slot.
Power to the slot is on, but the slot needs attention. Do not remove the
board from the slot.
Power to the slot is off, and the slot needs attention. You can remove
the board from this slot..
Power to the slot is off. You can remove the board from this slot.
Indicates This Status