Chapter 7
6. From the Logical Drive menu, choose the logical drive you want to
prepare for expansion.
7. From the Logical Drive menu for the drive you want to prepare, choose
Properties.
8. Choose Virtual Sizing.
9. On the Virtual Size menu, choose Enable, and confirm your choice.
10. Press Esc twice to return to the Logical Drive menu.
If you need to enable Virtual Sizing on another logical drive, choose the
logical drive and repeat steps 6 through 10.
11. If you have installed one or more HP NetRAID-3Si adapters, press Esc to
return to the Objects menu. Enable Virtual Sizing on the logical drives of
all adapters as necessary.
12. To exit, press Esc until you see the Exit? box, and choose Yes.
NOTE
Clearing a previous configuration does not reset the Virtual
Sizing setting for a logical drive. Use the Reset to Factory
Defaults option in HP NetRAID Express Tools to disable
Virtual Sizing for all logical drives, or manually change the
setting.
2. Start NT and Enter the Disk Administrator.
Start NT and enter the Disk Administrator. Here you see the new logical drive
shown as a single unpartitioned/unformatted drive of 500 GB. Although there
might be only 12 GB of real storage space on the logical drive, the Online
Capacity Expansion feature creates a virtual drive of 500 GB.
3. Partition and Format the Drive.
How you partition and format a drive depends on where you installed
Windows NT.
For drives that do not contain the Windows NT operating system, see
"Partition and Format Drives that do not Contain Windows NT" below.
If Windows NT was installed on a disk array, see "Partition and Format a
Drive that Contains Windows NT" below.
74
Preparing for Online Capacity Expansion