Chapter 11
3. Use View/Add Configuration to examine both configurations.
4. Resolve the configuration mismatch by selecting and saving one of the
two configurations.
Unresolved configuration mismatch between disk(s) and NVRAM on the adapter
Problem: The configuration stored in NVRAM does not match the configuration
stored on the drives, and configuration information on some drives conflict with
configuration information on other drives.
Suggested solution: Do the following to reconfigure your drives and restore your
data.
1. Press <Ctrl> <M> to start HP NetRAID Express Tools, as described in
Step L in Chapter 6.
2. From the Configuration menu, choose the View/Add Configuration
option.
3. Use View/Add Configuration to examine the configuration stored in
NVRAM. Write down all configuration information, including the SCSI
IDs of the physical drives in each array, the array and logical drive
numbers, stripe size, logical drive size, and the adapter settings.
4. Clear your configuration and reconfigure all of your drives using one of
the HP NetRAID utilities (HP NetRAID Assistant, HP NetRAID Config,
or HP NetRAID Express Tools). See the HP NetRAID User's Guide for
more information.
5. Restore your data from a backup copy.
1 Logical Drive Failed
Problem: One logical drive failed to sign on.
Suggested solution:
1. Verify that all physical drives are connected and powered on.
2. Use a utility, such as HP NetRAID Assistant or HP NetRAID Config, to
determine which physical drives are not responding and thereby make the
logical drive unavailable.
3. Correct the problem with the physical drive by reconnecting, replacing, or
rebuilding it.