HP D5970A - NetServer - LCII Configuration Manual page 52

Integrated hp netraid controller configuration guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 5
Figure 5-3. HP NetRAID Assistant Wizard Starting Window
3. Click one of the following configuration modes:
Select Custom if you want to define the arrays and logical drives and
set their parameters.
Select Automatic if you want the HP NetRAID Assistant Wizard to
define the arrays and logical drives (and set their parameters) for you
automatically.
When you select Automatic mode, you can toggle the Redundancy
check mark at the bottom of the window. If the Redundancy box
contains a check, the arrays are automatically configured with
redundant logical drives if possible. They will be assigned RAID levels
of 1 or 5, depending on the number and capacities of the physical
drives. If the Redundancy box is empty, all logical drives are
configured as RAID 0, which is not redundant. See "Automatic
Configuration" in Chapter 4 for a complete list of the rules used in
Automatic configuration.
46
Configuration