13.
Alternately and evenly tighten the liquid cooling unit/CPU 1 mounting screws to a torque of 6 in./
lbs.
Figure 5-64
14.
Lower the radiator to its closing position.
15.
Alternately and evenly tighten the liquid cooling unit/CPU 0 mounting screws to a torque of 6 in./
lbs.
Figure 5-65
ENWW
Tighten liquid cooling unit/CPU 1 mounting screws
Tighten liquid cooling unit/CPU 0 mounting screws
Removing and replacing components 107