Identifying A Blade Pc Using The Unit Identification Led - HP BladeSystem bc2000 - Blade PC User Manual

Bladesystem pc blade enclosure integrated administrator for cci v1.5
Hide thumbs Also See for BladeSystem bc2000 - Blade PC:
Table of Contents

Advertisement

5.
Click Reboot, Power Off or Power Off Immediately.
6.
Click Apply.
When the blade PC power is off, the Power Off button text becomes Power On.
To reboot the blade PC using the CLI, type:
REBOOT BAY <bay number> {[ , | - ] <bay number>} {FORCE} {[PXE | HDD | RBSU]}
NOTE:
This command sends a request to the blade PC in a given bay to perform a graceful shutdown
and then reboots the blade PC.
To power off the blade PC (immediately or otherwise) using the CLI, type:
POWEROFF BAY <bay number> {[ , | - ] <bay number>} {FORCE}
NOTE:
If the FORCE argument is invoked, the blade PC powers down immediately and could lose
data or become unstable.

Identifying a Blade PC Using the Unit Identification LED

NOTE:
You can perform this task only for a given blade PC bay by enclosure administrators and group
administrators with access rights to the blade PC bay.
The virtual button for the Unit Identification LED of the blade PC physically changes the state of the Unit
Identification LED on the front panel of the blade PC from off to on, or vice-versa. The Unit Identification
LED illuminates bright blue and is designed to help a technician quickly identify a specific blade PC in
the data center.
92
Chapter 7 Performing Common Administrative Tasks
ENWW