Dell PowerEdge C8000 Hardware Owner's Manual page 184

Dell poweredge c8220 hardware owner's manual
Hide thumbs Also See for PowerEdge C8000:
Table of Contents

Advertisement

Table 4-1. Fan Module Thermal Behavior Per Sled
Fan Module
BMC (Processor/Memory)/Server Enclosure Temperature Status
Status
OK/OK
Two fan
After 10
modules fail
minutes of
system
throttling
system will be
forced to shut
down
Three fan
System force
modules fail
shutdown
1 Locate the faulty fan in the back of the enclosure.
Each fan module has indicators that identify a faulty fan.
2 Remove the enclosure fan module. See the PowerEdge C8000 Systems
Hardware Owner's Manual for more information.
3 Examine the blades for debris. If debris is present, carefully remove it.
4 Reseat the faulty fan. See the PowerEdge C8000 Hardware's Owner
Manual for more information.
5 If none of the fan indicators show a fault LED and the blades do not power
on, log into the BMC web interface and check for status messages.
6 If the problem is not resolved, install a new fan.
7 If the new fan does not operate, see "Getting Help" on page 203.
184
Troubleshooting
OK/Fail
Fail/OK
After 10
After 10
minutes of
minutes of
system
system
throttling
throttling
system will be
system will be
forced to shut
forced to shut
down
down
System force
System force
shutdown
shutdown
Fail/Fail
After 10
minutes of
system
throttling
system will be
forced to shut
down
System force
shutdown

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge c8220

Table of Contents