Serial Port Connection List - Dell PowerEdge C8000 Hardware Owner's Manual

Dell poweredge c8220 hardware owner's manual
Hide thumbs Also See for PowerEdge C8000:
Table of Contents

Advertisement

See "Remote Access Configuration" on page 83 for details. Make sure the
last four options syncs with the host and client.
6 In the Server screen, select BMC LAN Configuration and press <Enter>.
7 In the BMC LAN Configuration screen, verify the following settings:
BMC LAN Port Configuration: Shared-NIC
BMC NIC IP Source: DHCP or Static (Use DHCP if your network
servers are using automatic assignment of IP addresses)
IP Address: 192.168.001.003
Subnet Mask: 255.255.255.000
Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 82 for details. Make sure the
host and client are on the same network
8 Press <Esc> to return to the System Setup screen. Press <Esc> again,
and a message prompts you to save the changes.

Serial Port Connection List

Signal Type
Setup Option
Remote
Access
Serial Console
Enabled
Redirection
Enabled
BMC Serial
Enabled
Over LAN
Enabled
Serial Port
Serial Port
Number
Address
COM1
3F8h/2F8h
COM1
2F8h/3F8h
COM2 as SOL 3F8h/2F8h
COM2 as SOL 2F8h/3F8h
Using the System Setup Program
OS
Output
Setting
ttyS0
Serial Port
ttyS1
ttyS1
Management
Port
ttyS0
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge c8220

Table of Contents