Table 2-1. D4 Token Table
Token
Setup Option
485A
NIC
Enumeration
485B
PCIe Generation Sets the PCI signaling rate at Gen3 8.0 Gigabits
485C
PCIe Generation Sets the PCI signaling rate at Gen2 5.0 Gigabits
485D
PCIe Generation Sets the PCI signaling rate at Gen1 2.5 Gigabits
485E
Reboot on WOL
(ROW)
485F
Reboot on WOL
(ROW)
4860
USB PORT with
BMC
4861
USB PORT with
BMC
4870
Force PXE Boot
only
4871
Force PXE Boot
only
4873
Active Processor
Cores
4877
PCIe Slot1
4878
PCIe Slot1
4879
PCIe Slot2
106
Using the System Setup Program
(continued)
Description
Sets PXE boot from Add-on NIC adapter to onboard
NIC.
bandwidth.
bandwidth.
bandwidth.
Disables ROW. (default)
The ROW repurposes the Wake on LAN (WOL)
signal to reboot the system board when the system is
in S0/S3 state.
Enables ROW.
ROW repurposes the WOL signal to reboot the
system board when the system is in S0/S3 state. When
a WOL packet is received by the NIC, the wake up
signal generated by the NIC shall cause a hardware
reboot of the system board.
Allows you to electrically disable the internal USB port
which contacts to BMC.
Allow the users to electrically enable the internal USB
port which contacts to BMC.
Disables PXE to be the boot device only.
Enables PXE to be the boot device only. The system
retrying to boot from PXE device.
This field controls the number of enabled 16 cores in
each processor. By default, the maximum number of
cores per processor will be enabled.
Allows you to electrically disable PCIe Slot1.
Allows you to electrically enable PCIe Slot1.
Allows you to electrically disable PCIe Slot2.