See
Table 6
Table 6
connUnitContol read return values
Switch setting
Online
Offline
Diagnostics
Other
Table 7
connUnitContol write control values
Control value
Cold Reset(3)
Offline(5)
Online(6)
Other
connUnitContact (1.3.6.1.3.94.1.6.1.23)
Contact information for this connectivity unit, and is persistent across boots.
Syntax
DisplayString (SIZE (0..79))
Access
Read-write
Status
Mandatory
Return value
The default is <sysContact undefined>. The string size is limited to a maximum of 64.
connUnitLocation (1.3.6.1.3.94.1.6.1.24)
Location information for this connectivity unit, and is persistent across boots.
Syntax
DisplayString (SIZE (0..79))
Access
Read-write
Status
Mandatory
Return value
The default is <sysLocation undefined>. The string size is limited to a maximum of 64.
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)
This value defines the event severity that is logged by this connectivity unit. All events of severity less than
or equal to connUnitEventFilter are logged in connUnitEventTable.
Syntax
FcEventSeverity
78
Fibre Alliance MIB Objects
and
Table 7
for connUnitControl values.
Return value
Online(6)
Offline(5)
Offline(5)
Unknown(1)
Result
Reset
Offline
Online
Not supported