Status
Mandatory
Return value
See
Table 17
Table 17
ConnUnitSensorMessage values
T
Sensor
Power Supply
Fan
Temperature Status
Temperature Value
connUnitSensorType (1.3.6.1.3.94.1.8.1.7)
The type of component being monitored by this sensor.
Syntax
INTEGER {
unknown(1)
other(2)
battery(3)
fan(4)
power-supply(5)
transmitter(6)
enclosure(7)
board(8)
receiver(9)
}
Access
Read-only
Status
Mandatory
Return value
See
Table 18
Table 18
ConnUnitSensorType return values
T
Sensor
Temperature
Fan
Power Supply
Voltage
connUnitSensorCharacteristic (1.3.6.1.3.94.1.8.1.8)
The characteristics being monitored by this sensor
86
Fibre Alliance MIB Objects
for connUnitSensorMessage return values.
Return value
Good/Bad/NotInstalled
Good/Bad/NotInstalled
Normal/Warm/Overheating/NotInstalled
Degrees in C
for connUnitSensorType return values.
Return value
Board(8)
Fan(4)
Power Supply(5)
Board(8)