Return value
See
Table 36
Table 36
fcFxPortPHysOperStatus return values
Status
Online
Offline
Diagnostics
Down
fcFxPortPhysLastChange (1.3.6.1.2.1.75.1.2.2.1.3)
The value of sysUpTime at the time the FxPort entered its current operational status. A value of zero
(0) indicates that the FxPort operational status has not changed since the agent last restarted.
Syntax
TimeStamp
Access
Read-only
Status
Current
Return value
Unsupported. Always returns error status NoSuchName.
fcFxPortPhysRttov (1.3.6.1.2.1.75.1.2.2.1.4)
The Receiver_Transmitter_Timeout Value (RT_TOV) of the FxPort. This is used by the receiver logic to
detect a loss of synchronization.
Syntax
Milliseconds
Access
Read-write
Status
Current
Return value
The default RT_TOV parameter is 100 (0x64). This is a global setting for the switch. If writing a
value to a port, all ports reflect this new value.
Fx Port Fabric Login table
The objects described in this section are in table format, indexed by switch index and port index. An
example of how to access one of these objects is: snmpget localhost public
fcFxPortFcphVersionAgreed.1.1. This table contains one entry for each FxPort in the Fabric
Element and the service parameters that have been established from the most recent Fabric Login
(implicit or explicit).
fcFxPortFcphVersionAgreed (1.3.6.1.2.1.75.1.2.3.1.2)
The version of FC-PH that the FxPort has agreed to support from the Fabric Login.
152 Fabric Element MIB Objects
for fcFxPortPhysOperStatus return values.
Return value
online(1)
offline(2)
testing(3)
linkfailure(4)