Installing the SAN Switch
Figure 8: Assembling the outer rails (HP 10000 series or comparable EIA cabinet)
40
b. Depending on the rack you are using, complete one of the following tasks:
— For an HP 10000 series or comparable EIA cabinet, install two #10-32 x
1/2-inch Phillips pan-head screws with captive star lock washers and two
#10 adapter washers in the upper and lower hole locations of the right rail.
Then install two #10-32 x 1/2-inch Phillips pan-head screws with captive
star lock washers and two #10 adapter washers in the upper and lower
hole locations of the left rail. See
Figure
8.
SAN Switch 2/8V, 2/16V and 2/16N Installation Guide