Environmental Requirements - HP AA979A - StorageWorks SAN Switch 2/8V Installation Manual

Hp storageworks san switch 2/8v, 2/16v and 2/16n installation guide, v4.2.x (aa-rvulb-te, april 2004)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

Technical Specifications

Environmental Requirements

To ensure proper operation, the switch must not be subjected to environmental
conditions beyond those for which it was tested. The ranges specified in
list the acceptable environment for both operating and non-operating conditions.
Table 19: Environmental Requirements
Condition
Temperature
Humidity
Altitude
Shock
Vibration
Air flow
Note:
intake vents on the nonport side of the switch. The temperature inside the switch can be
up to 75° Celsius during switch operation.
If the internal temperature range exceeds the operating ranges of the components, the
LEDs, error messages, and Fabric Watch alerts will indicate a problem. Enter the
tempshow or Fabric Watch commands to view temperature status.
96
Acceptable Range During
Operation
to +40 C
-10
(12 to 122 F)
20% to 85% RH non-condensing,
at 40 C, with maximum gradient of
10% per hour
0 to 10,000 ft (3 km) above sea
level
20 G, 6 ms duration, half sine wave
0.5 G, 5-500 Hz
Normal: 24 cubic ft/minute
1 fan failed remaining running at
high speed): 30 cfm
All fans running at high speed: 44
cfm
The 0° - 40° Celsius range applies to the ambient air temperature at the air
Acceptable Range During
-50 to 100 C (-122 to
212 F)
10% to 85% RH
noncondensing, at 70° C
0 to 39,370 ft (12 km) above
sea level
15 G, 12-18 ms duration,
trapezoid
5-500 Hz
2.0 G,
None required
SAN Switch 2/8V, 2/16V and 2/16N Installation Guide