Notification Type – (Configurable only if the Notification Version is SNMPv2.) Select
the type of notification sent. The possible field values are:
–
Traps – Traps are sent.
–
Informs – Informs are sent only when SNMPv2 is enabled.
•
Community String – Enter the community string of the trap manager.
•
Notification Version – Select the trap type. The possible field values are:
–
SNMPv1 – SNMP Version 1 traps are sent.
–
SNMPv2 – SNMP Version 2c traps are sent.
•
UDP Port – Enter the UDP port used to send notifications. The default UDP port is 162.
•
Timeout – Enter the amount of time (in seconds) the device waits before re-sending
informs. The default is 15 seconds.
•
Retries – Enter the amount of times the device re-sends an inform request. The default is 3
seconds.
2. Select the trap entry.
3. Enter the fields in the first row.
4. Click Apply to update the device.
To add a new SNMP trap:
1. Click System > SNMP > SNMPv1/v2 > Trap Configuration. The SNMPv1/v2 Trap
Configuration screen displays.
2. Enter the fields in the first row.
3. Click Add to update the device.
To remove an SNMP trap:
1. Click System > SNMP > SNMPv1/v2 > Trap Configuration. The SNMPv1/v2 Trap
Configuration screen displays.
2. Select the entry to be removed.
3. Click Delete to remove the entry.
SNMPv3
The SNMPv3 menu contains the following options:
•
"Engine ID"
Managing System Settings
GS700AT Series Smart Switch Software Administration Manual
v1.0, March 2008
3-11