3. Secure the Case, lower with the screws.
[Adjustment]
Perform the platen gap adjustment by referring to the Adjustment section at the end of
this chapter.
CPT-B (M3x12)
[0.59 to 0.78 N • m
[6 to 8 kgf • cm)]
Rev.B
Portion C
Lead wires of the Detector ass'y
TM-U200D/U200PD Technical Manual
Lower case
Portion D
Portion A
Plate, upper
CPT-B (M3x12)
[0.59 to 0.78 N • m
[6 to 8 kgf • cm)]
Disassembly, Assembly, and Adjustment 5-33
Portion B