Download Print this page

Teac HS-2 Technical Information page 33

Rs-232 documentation for hs-8
Hide thumbs Also See for HS-2:

Advertisement

FLASH READY SLOT RETURN
This is the return command in response to the command "FLASH READY SLOT SENSE [7F045D]."
It returns the information about the flash-loaded slot (take).
Command
FF
Category Code
04
Sub Command
DD
Machine ID
0
Data
4 bytes to 119 bytes
Data 5
Data 6
Data 7
Data 8
Data 9 – Data123
・ The slot (take) data is between 0 bytes and 115 bytes.
・ A take preceding the starting slot (take) and a take that is not specified for the slot (take) data are "not
flash-loaded."
Request/Preset
FLASH READY SLOT SENSE [7F045D]
CHANGE FLASH PAGE
This command indicates that the flash page of the controlled device has been updated.
Command
FF
Category Code
04
Sub Command
F6
Machine ID
0
Data
0 bytes
Request/Preset
none
ONLINE RETURN
This is the return command in response to the command "ONLINE [7F0511]."
It returns the On/Off state of the Online mode.
Command
FF
Category Code
05
Sub Command
91
Machine ID
0
Parameter
2 bytes
Data 5
Data 6
0
0
0
1
Request/Preset
ONLINE [7F0511]
Description
Tens digit of the slot (take) number
Ones digit of the slot (take) number
Thousands digit of the slot (take) number
Hundreds digit of the slot (take) number
Slot (Take) data
Description
Online OFF
Online ON
TASCAM HS-8 RS-232C Protocol Specification
Remarks
The starting slot (take) number about which
information is provided
Example) 2100: take 21
One-byte data (1 character) shows the
loading status of the slot (take).
"0" (30h): Not flash-loaded
"1" (31h): Flash-loaded
Example: To show the statuses of 20 slots
(takes), 20 bytes (20 characters) of data "0"
or "1" are contained.
Remarks
Online mode: off (monitor play)
Online mode: on (online play)
33
TEAC Corporation

Advertisement

loading

This manual is also suitable for:

Hs-8