Download Print this page

Teac HS-2 Technical Information page 17

Rs-232 documentation for hs-8
Hide thumbs Also See for HS-2:

Advertisement

CLOCK DATA RETURN
This is the return command in respond to the command "CLOCK DATA PRESET [27]."
It returns the currently specified date and time values.
Command
A7
Machine ID
0
Data
12 bytes
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Data 9
Data 10
Data 11
Data 12
Request/Preset
CLOCK DATA PRESET [27]
DIGITAL VOLUME DATA RETURN
This is the return command in respond to the command "DIGITAL VOLUME DATA PRESET [2F]."
It returns the specified digital volume in decibels (dB).
Command
AF
Machine ID
0
Data
4 bytes
Data 1
Data 2
Data 3
Data 4
・ If the volume is set to -∞ (minus infinity) dB, "AAAA" is transmitted to Data 1 to Data 4.
Request/Preset
DIGITAL VOLUME DATA PRESET [2F]
AUTO CUE SELECT RETURN
This is the return command in response to the command "AUTO CUE SELECT [30]."
It returns the On/Off status of the auto cue function.
Command
B0
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
Request/Preset
AUTO CUE SELECT [30]
Description
Tens digit of the year
Ones digit of the year
Tens digit of the month
Ones digit of the month
Tens digit of the day
Ones digit of the day
Tens digit of the hours
Ones digit of the hours
Tens digit of the minutes
Ones digit of the minutes
Tens digit of the seconds
Ones digit of the seconds
Description
Remarks
Ones digit of the
setting
First decimal place of
the setting
Example: "0512": -20.5dB
+:0/-:1
Tens digit of the
setting
Description
Remarks
Auto Cue Off
Auto Cue On
TASCAM HS-8 RS-232C Protocol Specification
Remarks
17
TEAC Corporation

Advertisement

loading

This manual is also suitable for:

Hs-8