Download Print this page

Teac HS-2 Technical Information page 14

Rs-232 documentation for hs-8
Hide thumbs Also See for HS-2:

Advertisement

REMOTE/LOCAL SELECT
Enables or disables operation on the controlled device.
A return command is returned only if Sense [FF] is specified.
Command
4C
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
F
F
・ If data other than the above is received, the HS-8 will transmit ILLEGAL [F2].
Return
REMOTE/LOCAL SELECT RETURN [CC]
PLAY MODE SELECT
Sets Play mode for the controlled device.
To check the Play mode setting, use the command "PLAY MODE SENSE [4E]."
Command
4D
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
・ If data other than the above is received, the HS-8 will transmit ILLEGAL [F2].
Return
none
PLAY MODE SENSE
Requests that Play mode of the controlled device be returned.
Command
4E
Machine ID
0
Data
none
Return
PLAY MODE RETURN [CE]
MECHA STATUS SENSE
Requests that the operation status of the controlled device be returned.
Command
50
Machine ID
0
Data
none
Return
MECHA STATSU RETURN [D0]
TRACK (TAKE) No. STATUS SENSE
Requests that the current take number be returned.
Command
55
Machine ID
0
Data
none
Return
TRACK (TAKE) No. STATUS RETURN [D5]
CURRENT TRACK (TAKE) INFORMATION SENSE
Requests that the information about the current take be returned.
Command
57
Machine ID
0
Data
none
Return
CURRENT TRACK (TAKE) INFORMATION RETURN [D7]
Description
Remarks
Remote
Only remote operation via CONTROL I/O (RS-232C, RS-422, PARALLEL)
will be enabled. Key operations on the device's panel will be disabled.
Local
Remote operation, and key operation on the device's panel will be enabled.
Sense
Requests that the current setting be returned.
Description
Remarks
All Take
Plays all takes in the current folder
One Take
Plays the current take only
TASCAM HS-8 RS-232C Protocol Specification
14
TEAC Corporation

Advertisement

loading

This manual is also suitable for:

Hs-8