C
ALIBRATION
9 Place the ED-100 over the specified patch on the Measurement Page, making sure to center the
sample aperture over the patch. Press Measure to take the measurement.
For a more accurate measurement, place several plain sheets of paper beneath the
N
:
OTE
Measurement Page to block underlying colors from being read by the instrument.
If you have specified multiple clicks per patch, continue pressing Measure to take the
required number of measurements. We recommend that you move the ED-100 slightly
after each measurement while keeping it within the patch circle.
When the patch has been measured successfully, a check mark appears in the patch
preview in the Measurements window. The window identifies and highlights the next
patch to be measured.
10 Repeat
step 9
to measure each successive patch on the Measurement Page.
Start with A1 and continue down Column A. When you have finished measuring all the
patches in Column A, proceed to Column B in the same manner until all columns have
been measured.
To retake a measurement, select the desired patch preview in the Measurements window
and measure the patch on the page using the ED-100.
N
:
You must take the measurements in the order outlined in the Measurements
OTE
window and on the measurement page.
11 When all the patches have been read successfully, click Accept.
12 Click Apply in the Calibrator dialog box.
The new calibration measurement is implemented.
13 Click OK in the Information dialog box.
This completes the CX3641MFP calibration process.