1
Place grayscale strip
face down
2
Place color measurement
page face down over
grayscale strip
C
ALIBRATION
13 Place the Kodak Gray Scale strip, Kodak Color Control Patches strip, and scanner
measurement page in the correct positions on the copier/printer glass for scanner calibration.
Place the Gray Scale strip face down on the copier/printer glass so that it is centered along
the top edge of the scanner measurement page. Then place the Color Scale strip face down
on the copier/printer glass so it is centered below the Gray Scale strip, keeping a distance
of 0.25 inch to 0.5 inch between the two strips. Finally, place the scanner measurement
page face down over the strips.
14 Click Continue to start the scanner measurement.
When the measurement process completes, the information dialog box appears.
15 Click Continue to complete scanner calibration.
16 Place the Kodak Gray Scale strip face down on the copier/printer glass.
Place the strip along the top edge of the copier/printer so that it is centered between the
paper width marks on the copier/printer.
1
17 Place the ColorCal measurement page face down over the grayscale strip.
Make sure that the patches on the grayscale strip do not overlap the color patches.
Close the platen glass cover, being careful not to move the grayscale strip and color
measurement page.