Tandberg Data SLR AUTOLOADER Service And Repair Manual page 67

Compact tape cartridge loader
Hide thumbs Also See for SLR AUTOLOADER:
Table of Contents

Advertisement

Boot Firmware Error Codes
FSC
Display Message
B001
Boot ROM CRC Error
B002
Code ROM CRC Error
B003
Boot RAM Test Failed
B004
Boot CPU Test Failed
B005
Boot ENC Test Failed
B006
Boot UART Error
B007
Boot Comm Open
Error
Power-On Self Test Error Codes
FSC
Display Message
4001
Uart 1 Error
4002
Uart 2 Error
Menu Mode Error Codes
FSC
Display Message
5610
BREAK Detected
5611
DACI Locked
5612
DACI Busy
5613
Drive Busy
5614
Illegal CDB
5615
Illegal Parameters
5617
Unknown Command
5618
DACI Poll Error
5619
Illegal Data
567F
Status Timeout
Tandberg SLR Autoloader Service and Repair Manual
Description
A power-up error was
detected.
Description
Internal serial port error Robotics Assembly
Description
Unexpected status
returned from drive.
No response from
drive.
Source of Failure
Robotics Assembly
Source of Failure
Source of Failure
Drive Assembly
Suggested Action
Press the REBOOT
button on the Control
Panel or flash with new
firmware. See Chapter
4.
Suggested Action
Press the REBOOT
button on the Control
Panel.
If this does not correct
the error, contact
Tandberg Data.
Suggested Action
Press the REBOOT
button on the Control
Panel.
63

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLR AUTOLOADER and is the answer not in the manual?

Questions and answers

Table of Contents