4.25 Fluorescent lamp
5. Removing PCB-ASSY cell
<Procedure>
1) Remove the PCB-ASSY cell from the back light unit.
2) Remove thoroughly remaining double-sided tape on the back of cell.
Caution: 1. One point of the upper of cell is fixed with double sided tape. Peel off
slowly so as not to break the cell.
2. Be careful not to peel off the light-shield tape at the upper, lower, right
and left.
??
Remove the cell while
peeling off the double
-sided tape (1 point).
PORTEGE A100 Maintenance Manual (960-460)
Figure 4-49 Replacing TDM fluorescent lamp(6)
4 Replacement Procedures
Cell with PCB
4-61