Cooling Sub-System

Intel® Server Systems SR1530CL/SR1530HCL/SR1530HCS
and SR1530CLR/SR1530HCLR/SR1530HCLSR
3.
Cooling Sub-System
The cooling sub-system consists of two 97 x 94 x 33 blower fan, a CPU air duct, and a
PS/electronics bay isolation air baffle. The SR1530CL also includes one additional 40 x 40 x 15
PCI cooling fan. These components are used to provide the necessary cooling and airflow to
the system. A fan on the processor heat sink is not needed.
To maintain the necessary airflow within the system, the air duct and the top cover must be
properly installed.
®
Note: The Intel
Server Systems SR1530CL/SR1530HCL/SR1530HCLS and
SR1530CLR/SR1530HCLR/SR1530HCLSR do not support redundant cooling. Should a fan
blower fail, the system should be powered down as soon as possible to replace the failed fan
blower.
AF001524

Figure 10. Fan Module Assembly - SR1530CL/SR1530CLR (SATA)

14
Revision 2.2
Intel order number D71005-005