Beep/symptom
3-1-4 (Time of day clock
failed)
3-2-1 (Serial port failed) v System board
3-2-2 (Parallel port
failed)
3-2-4 (Failed comparing
CMOS memory size
against actual)
3-3-1 (Memory size
mismatch occurred)
3-3-2 (Critical SMBUS
error occurred (I2C bus
error)
3-3-3 (No optional
memory in the system)

No beep symptoms

No Beep Symptom
No beep and no video.
(System attention LED is off)
No beep and no video.
(System attention LED is on)
No ac power
No beep and no video

Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197,do not replace a
FRU/action
1. Battery
2. System board
v System board
1. DIMM
2. System board
3. Battery
1. DIMM
2. System board
3. Battery
1. Disconnect server power, wait 30 seconds and retry.
2. System board.
3. Microprocessor/PCI riser card.
4. DIMMs.
5. Hard disk drive backplane.
6. Hard disk drive power cable.
1. Install or reseat the memory modules.
2. DIMMs.
3. System board.
FRU/Action
v System board
v See "Information panel system error LED".
1. Check the power cord.
2. Power supply.
v See "Undetermined problems" on page 77.
FRU. The description for these error codes are:
000
The test passed.
195
The Esc key was pressed to abort the test.
197
This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.