Juniper JUNOSE 10.0.3 - RELEASE NOTES 4-30-2010 Release Note page 73

For e series broadband services routers
Table of Contents

Advertisement

The JUNOSe Command Reference Guide N to Z omits the following information
for the qos-interface-parent command, beginning with JUNOSe Release 9.2.0
in which it was introduced:
The qos-interface-parent command is available in Interface Configuration
mode, as well as in QoS Interface Set Configuration and QoS Interface Superset
Configuration modes. The syntax for this command in Interface Configuration
mode is:
[ no ] qos-interface-parent interfaceSetName
where:
interfaceSetName—Name of the QoS interface set that is the parent of the
interface
This command assigns a QoS interface set as the parent for the member
interface. The no version deletes the parent from the interface.
The description of the redundant-port command in the JUNOSe Command
Reference Guide N to Z and JUNOSe Link Layer Configuration Guide, Chapter 6,
Configuring 802.3ad Link Aggregation and Link Redundancy, Configuring Ethernet
Link Redundancy section, inadvertently omits the default values of the following
keywords:
failover timeout: 1000 milliseconds
packet-sampling: disabled
delay: 0 milliseconds
auto-revert: disabled
The description of the shaping-rate command in the JUNOSe Command
Reference Guide N to Z incorrectly states the range and units for the shapingRate
argument. The correct range for the shapingRate argument is 1–1000000000
bps/kbps. You can set the shaping rate to vary from 1 bps to 1000 gbps (which
is denoted by entering 1000000000 kbps in the CLI for this command).
In the JUNOSe Command Reference Guide N to Z for JUNOSe Release 9.3.x,
Release 10.0.x, and Release 10.1.x, the description of the fileName variable in
the service check-config command incorrectly stated that it represented an
action for an empty service name tag. The fileName variable available with this
command refers to the name of an existing configuration file (.cnf) that needs
to be validated for corruption.
The tables in the Interface Types and Specifiers section of Chapter 1, Command
Reference Topics, in the JUNOSe Command Reference Guide erroneously state
that the maximum number of PPPoE subinterfaces per Ethernet (GE/FE) line
module is 4094. The correct number for an ERX router is 8000 and for an E120
or E320 router, it is 16,000.
Release 10.0.3
65
Errata

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junose 10.0.3

Table of Contents