Bringing the Replaced PCG Online
To bring the replaced PCG online, use the following CLI command:
user@host> request chassis pcg slot slot-number online
user@host> request chassis pcg slot 0 online
Online initiated, use 'show chassis environment pcg" to verify
The PCG in slot 0 is brought online.
To verify that the replaced PCG is online, follow these steps:
1. Display the Replaced PCG Environmental Status on page 602
2. Display PCG Messages in the System Log File on page 603
3. Display PCG Error Messages in the Chassis Daemon Log File on page 603
To verify that the replaced PCG is online, use the following CLI command:
user@host> show chassis environment pcg
user@host> show chassis environment pcg
PCG 0 status:
State
Temperature
Frequency:
Setting
Measurement
Power:
3.3 V
5.0 V bias
8.0 V bias
CMB Revision
PCG 1 status:
State
Temperature
Frequency:
Setting
Measurement
Power:
3.3 V
5.0 V bias
8.0 V bias
CMB Revision
When the replaced PCG is brought online, it does not automatically become master.
It remains as the backup PCG until the master PCG fails, or you manually switch it
to master by using the request chassis pcg online slot 1 CLI command.
Online
30 degrees C / 86 degrees F
125.00 MHz
125.01 MHz
3278 mV
4986 mV
8222 mV
12
Online - PFE clock source
43 degrees C / 109 degrees F
125.00 MHz
124.95 MHz
3269 mV
4991 mV
8222 mV
12