Step 2: Display the CFEB Status
To display CFEB status to show mastership, use the following CLI command:
Action
Sample Output
user@host> show chassis cfeb
CFEB status:
Slot 0 information:
Slot 1 information:
The command output displays which CFEB is master and backup, as well as other
What It Means
environmental and memory information.
Display CFEB Alarms
To display CFEB alarms, see "Checking for CFEB Alarms" on page 423. For
Action
conditions that trigger CFEB alarms, see "Display the Current Router Alarms" on
page 61.
Verifying CFEB Failure
To verify CFEB failure, see "Verifying CFEB Failure" on page 621.
Action
Returning the CFEB
To replace the CFEB, see "Return the Failed Component" on page 86, or follow the
Action
procedure in the M10i Internet Router Hardware Guide.
user@host> show chassis cfeb
State
Intake temperature
Exhaust temperature
CPU utilization
Interrupt utilization
Heap utilization
Buffer utilization
Total CPU DRAM
Internet Processor II
Start time:
Uptime:
State
Intake temperature
Exhaust temperature
CPU utilization
Interrupt utilization
Heap utilization
Buffer utilization
Total CPU DRAM
Internet Processor II
Start time:
Uptime:
Chapter 47: Monitoring Redundant CFEBs
Master
29 degrees C / 84 degrees F
38 degrees C / 100 degrees F
3 percent
0 percent
10 percent
22 percent
128 MB
Version 1, Foundry IBM, Part number 164
2004-09-28 03:07:54 PDT
9 days, 18 hours, 36 minutes, 15 seconds
Backup
29 degrees C / 84 degrees F
38 degrees C / 100 degrees F
3 percent
0 percent
10 percent
22 percent
128 MB
Version 1, Foundry IBM, Part number 164
2004-09-28 03:07:54 PDT
9 days, 18 hours, 36 minutes, 15 seconds
!
621
Display CFEB Alarms
Need help?
Do you have a question about the JUNOS - NETWORK OPERATION GUIDE REV1 and is the answer not in the manual?